INPUT CONDITIONS |
INPUT VOLTAGE |
Vac |
90 to 130 / 180 to 260 |
INPUT CURRENT |
Aac |
Max 1.3 |
FREQUENCY |
Hz |
47 to 63 |
EFFICIENCY |
% |
Min. 78 |
INRUSH CURRENT |
A |
Max. 25 |
OUT CONDITIONS |
OUTPUT VOLT ADJ |
% |
¡¾ 5 |
LINE REGULATION |
% |
¡¾ 1 |
LOAD REGULATION |
% |
¡¾ 1 |
OVER VOLTAGE |
- |
SHUT DOWN METHOD MANUAL RESET |
OVER CURRENT |
- |
CONSTANT CURRENT LIMITING WITH AUTO RECOVERY |
HOLD UP TIME |
§Â |
Min. 20 |
PEAK OUTPUT |
% |
Max. 110 |
RIPPLE & NOISE |
mV p-p |
1% + 50 |
Enduring Voltage & Isolation |
INPUT ¢¢ F.G (Chassis) |
Vac |
1,500 for 1Minute (Nominal Temperature and Humidity) |
INPUT ¢¢ OUTPUT |
Vac |
3,000 for 1Minute (Nominal Temperature and Humidity) |
OUTPUT ¢¢ F.G |
Vac |
600 for 1Minute (Nominal Temperature and Humidity) |
INPUT ¢¢ OUTPUT ¢¢ F.G |
M§Ù |
Min 100 Up (500Vdc Insulation Tester) |
Operating Condition |
OPERATING TEMPERATURE |
¡É |
-10 ~ +50 |
COOLING METHOD |
- |
Nature Cooling |
STORAGE TEMPERATURE |
¡É |
-20 ~ +80 |
HUMIDITY |
% |
10 ~ 90 RH |
VIBRATION |
10 ~ 55Hz at 1G, 3 Minutes period, 30 Minutes along X, Y and Z axis |
IMPACT |
10G for 20ms once on each X, Y and Z axis |
SAFETY |
SAFETY APPROVED |
CE (TUV) |
EMI & EMS |
EN61204-3:2000+A1:2001, EN61000-3-2:2000, EN61000-3-3:1995+A1:2001 |